wmpazar
aşk ritmi
. search
.
.
.
.
.
FCRI
.
Fluid Control Research Institute
.
.
FLUID CONTROL RESEARCH INSTITUTE
.
Under Ministry of Heavy Industries & Public Enterprises, Govt: of India
.
.
.
.
. PROJECTS
. PUBLICATIONS
. TENDERS
. CAREER
. ACCREDITATIONS
. FCRI IN THE PRESS
. REQUEST A SERVICE
.
.

Have you a Flow Measurement Problem/Issue

.

- OUR SERVICES -

. Endurance testing of Critical Components
. Testing . On-site assignments
. Calibration . Third party certification

more

.

- OUR SERVICES -

. Register For Training
. Upcoming Training Courses
more

.





.



.



.

.
Fluid Control Research Institute Fluid Control Research Institute Fluid Control Research Institute
Fluid Control Research Institute Fluid Control Research Institute Fluid Control Research Institute
Fluid Control Research Institute Fluid Control Research Institute Fluid Control Research Institute
Fluid Control Research Institute Fluid Control Research Institute Fluid Control Research Institute
.


FACILITIES

  ELECTRONIC & INSTRUMENTATION LABORATORY

The Electronic and Instrumentation laboratory has refined instruments which have a high degree of accuracy. They are maintained to ensure a high degree of performance. Tailored Instrumentation setups are made for special experiments at the Water & Air flow laboratories. Data Acquisition Systems coupled with dedicated software ensure a high degree of repeatability and reliability. The laboratory has the capability to cater to the calibration of parameters like Voltage AC/DC, Current AC/DC, Frequency, Time, Capacitance, Inductance, Resistance and Temperature. The laboratory is also involved in


Electronics & Instrumentation

.Development of new type of flowmeters like Thermal mass flowmeters for measurement of very small flows which is an import substitution.

.Design and fabrication of fully automatic, dedicated test loops for specialised applications. The table gives the testing facilities of the laboratory.


Parameter Instrument used
for testing
Range % Uncertainty
Voltage Multifunction calibrator 1 µV to 1000V AC & DC +/- 0.0002 to +/- 0.4
Current
Multifunction calibrator

Transconductance

Amplifier


1 µ A to 11A AC & DC

0.2mA to 100A

AC & DC


+/-0.0042 to +/-0.9

+/-0.02 % O/P to

+/- 0.02% of range

Resistance Multifunction calibrator 1 Ohm to 100M Ohm +/- 0.007 to 0.0109
Capacitance LCR Meter 1 Pf to 100 m F 0.1
Inductance LCR Meter 100 m H to 10H 0.1
Frequency Function generator 1MHz to 20 MHz
Temperature Water Bath

Oil Bath

Fluid Bath

High temperature calibration system
+10 to +100 deg.C

-30 to +150 deg.C

+30 to +700 deg.C

+5 to +1100 deg.C
Stability +/-0.1 deg.C

Stability +/-0.01 deg.C

Stability +/- 0.2 deg.C

+/- 0.01 deg.C(Dead bed)

Stability +/-0.25 deg.c
Time Universal Counter 1 nS to 105 S 0.00001% to 0.007%


TRAINING PROGRAM
.

Frequently Asked QuestionsIFeedbackI Flotek.g IFCRI Intranet Page IPrivacy PolicyISitemap

.
.